The JI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     
 


The Journal of Immunology, 1962, 88: 545-550.
Copyright © 1962 by The American Association of Immunologists, Inc.

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Glenn, W. G.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Glenn, W. G.

Quantitative Analyses by Diffusion Column Reactions1

III. Antigen and Antiserum Concentration Differences from Diffusion Measurements of Simple Homologous Reactions

William G. Glenn

From the Microbiology-Cellular Biology Branch, School of Aerospace Medicine, USAF Aerospace Medical Center (ATC), Brooks Air Force Base, Texas

Abstract

1. Experimental interpolation of slope K (diffusion (mm) vs {surd}min) for SD columns of albumin homologous reactions resulted in the detection of concentration differences of 0.10 mg N2/ml (0.06% protein) of antigen and 0.010 mg N2/ml of antibody in 75% and 50% of the respective paired slope comparisons within specific antigen and antibody ranges.
2. Comparison of the Kjeldahl concentrations with the same concentrations estimated from diffusion measurements for both antigen and antibody strengths in SD columns were made using results from regression of K on log of the appropriate reactant concentration. The data used were strictly selected for linearity and reproducibility. For 30 antigen derivations involving Fractions II and V homologous systems at three antibody levels, the mean deviation was 3.44%. The smallest deviation was -0.29% or 0.001 mg antigen N2 lower for the predicted as compared to the Kjeldahl concentrations.
3. Estimated homologous antibody concentrations from rigidly selected data and curves (K regressed on the logarithm of the antibody concentrations), when compared with Kjeldahl values, showed an average deviation of 2.54% for 50 antibody derivations at five antigen levels for Fractions II and V in SD columns. The over-all mean difference (sign ignored) between Kjeldahl and diffusion—estimated values—was 0.007 mg antibody N2/ml.
4. The limits of resolution for reactant concentration differences in SD column reactions at certain ranges are discussed in detail.

Footnotes

1 The contents of this paper reflect the personal views of the author and are not to be construed as a statement of official Air Force policy.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
This Website Copyright © 1962 by The American Association of Immunologists, Inc. All rights reserved.
All Contents Copyright © 1962 by The American Association of Immunologists, Inc. All rights reserved.