The JI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     
 


The Journal of Immunology, 1939, 37, 305 -320
Copyright © 1939 by The American Association of Immunologists, Inc.

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Gara, P. F.
Right arrow Articles by Bullowa, J. G. M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by de Gara, P. F.
Right arrow Articles by Bullowa, J. G. M.

Pneumococcal Capsular Polysaccharide in Urine; Detection by Precipitation and Centrifugation1

Paul F. de Gara, Samuel C. Bukantz2 and Jesse G. M. Bullowa

Medical Service, Harlem Hospital, Department of Hospitals, New York City and the Littauer Pneumonia Research Fund of New York University, College of Medicine

Abstract

The minimal amount of specific soluble substance detectable after its addition to normal urine, and the optimal amount of rabbit antibody required for detection, was investigated for pneumococcal types I, II, III, IV, V, VII, VIII, and XIV. The minimal concentration detectable for I, III, IV, and XIV was 1:200,000 and for II, V, VII, and VIII, 1:400,000. The optimal antibody unitage required varied from 125 to 500 units per cubic centimeter. Concentration of urine containing specific soluble substance yielded roughly equal increases in the concentration of specific soluble substance. The precipitative reaction in urine has been successfully employed to identify the infecting type of pneumococcus in patients whose sputa yielded several types. Pooled rabbit sera, as used in Neufeld typing methods, were successfully employed for the detection of capsular polysaccharide in urine. Centrifugation at 2,000 r.p.m. for 30 minutes, immediately after mixture of urine and antiserum, yielded positive reactions in the full expected range. These reactions are generally more evident than are the reactions obtained after 20 hours by the usual procedure of incubation at 37° for 2 hours and refrigeration overnight.

Upon the basis of these experiences we propose the following procedure for the routine detection of urinary polysaccharide, for the 8 types studied (table 5).
Figure 1

Footnotes

1 This study received additional financial support from the Metropolitan Life Insurance Company, and from Mr. Bernard M. Baruch, Mr. Bernard M. Baruch, Jr., Miss Belle N. Baruch, and Mrs. H. Robert Samstag.

2 Research Fellow, Pneumonia Service, Harlem Hospital.




This article has been cited by other articles:


Home page
Arch Intern MedHome page
S. C. BUKANTZ, P. F. de GARA, and J. G. M. BULLOWA
CAPSULAR POLYSACCHARIDE IN THE BLOOD OF PATIENTS WITH PNEUMOCOCCIC PNEUMONIA: DETECTION, INCIDENCE, PROGNOSTIC SIGNIFICANCE AND RELATION TO THERAPIES
Arch Intern Med, February 1, 1942; 69(2): 191 - 212.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
This Website Copyright © 1939 by The American Association of Immunologists, Inc. All rights reserved.
All Contents Copyright © 1939 by The American Association of Immunologists, Inc. All rights reserved.